Print-no. 250 020 1
02/2011
Operating Manual blueMatic EAV 43
Aug. Winkhaus GmbH & Co. KG · Berkeser Str. 6 · D-98617 Meiningen · www.winkhaus.de
Subject to technical changes
Error Indication Possible cause Troubleshooting
Power failure when/
during:
a) the door is locked •thedoorcanbeopera-
ted mechanically (pro-
le cylinder/handle)
b) the door is open,
lock is unlocked
the door is possibly
not held by the latch
•themotorisnotin
starting position
•closethedoorbypre-
locking the main bolt,
if necessary
c) the unlocking
procedure
when the door is
locked again, pos-
sibly the hook, main
bolt do not lock
completely
•themotorisnotin
starting position
•doorcanbeoperated
mechanically (prole
cylinder/handle), if
motor has returned
to starting position Ü
completely functions
EAV does not ope-
rate with remote but
LED is illuminating.
Door doesn‘t open •Remotebatterydead
• Outofrangetothe
remote control
• Remotecontrolnot
autthorized
• Replacebatteryin
remote control
• Operateremotecontrol
within 30 mtrs. (uno-
structed)
• Checkremotecontrol
programmed
Does not operate
with remote control,
red LED is not illu-
minating.
• Remotebatterydead • Replacebatteryin
remote control
7 Technical specications
7.1 Power supply
Primary voltage: 100 - 240 V AC; 50/60 Hz
Secondary voltage: 12 V DC stabilized
Current: 2 A
Dimensions: 77 x 92 x 55 mm [3.031 x 3.622 x 2.165”]
Weight: approx. 0.3 kg
Installation: top hat mounting rail